ORIGINAL ARTICLE
Year : 2014  |  Volume : 2  |  Issue : 2  |  Page : 47-50

Patient safety and stethoscopes


20B Scotland Street Lane West, Edinburgh EH3 6PT, Foundation Year 1 Doctor, NHS Fife, UK

Correspondence Address:
Ian James Bruce Young
20B Scotland Street Lane West, Edinburgh EH3 6PT, Foundation Year 1 Doctor, NHS Fife, UK

Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Background: It has been suggested that the use of stethoscopes may transmit infection between patients and yet stethoscope cleaning protocols lack consistency of guidance as to where, when and how stethoscopes should be cleaned. We have assessed the difference in microbiological colonisation between non-dedicated and patient dedicated stethoscopes and between the stethoscope diaphragm and neck. Methods: An observational study over an 8-day period at a secondary care hospital. We analysed 104 samples comprising matched diaphragm and neck data for each of 26 non- dedicated and 26 patient dedicated stethoscopes. The diaphragm and neck of each stethoscope were swabbed and processed using standard microbiology techniques. Results: 98% of stethoscopes were colonised. There was a lack of evidence for a true difference in colonisation levels between the stethoscope diaphragm and neck (n Ό 104, p Ό 0.752(OR1.000 95%CL (0.230e4.345)) Cohen's effect size index Ό 0.000) or between dedicated and non-dedicated stethoscopes (n Ό 104, p Ό 1.000(OR3.118 95%CL (0.121 e80.190))). Conclusions: Importance in maintaining the hygiene of stethoscopes is underplayed. An effective patient safety culture will not merely respond to recognised risk but will identify and mitigate potential risk. These data suggest the entirety of the stethoscope will become colonised regardless of its environment. A good patient safety intervention will make doing the right thing the easy thing. Here we argue for cleansing the entirety of the stethoscope before and after patient contact.


[PDF Not available]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1743    
    Printed137    
    Emailed1    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal